Intra-observer agreement in single and joint double readings of contrast-enhanced breast MRI screening for women with high genetic breast cancer risks
-
Hugo C1,
Hurtevent G2,*,
Ferron S2,
Boisserie-Lacroix M2,
Longy M3,
Floquet A4,
Brouste V5 and
Asad-Syed M2
- 1 Department of Radiology, Centre Hospitalier de Pau, France
- 2 Departments of Radiology, Institut Bergonié, Bordeaux, France
- 3 Departments of Pathology, Institut Bergonié, Bordeaux, France
- 4 Department of Medical Oncology, Institut Bergonié, Bordeaux, France
- 5 Clinical and Epidemiological Research Unit, Institut Bergonié, Bordeaux, France
*Corresponding author: Hurtevent G, Department of Radiology, Institut Bergonié, Comprehensive Cancer Center, 229 cours de l’Argonne, 33076 Bordeaux Cedex, France, Tel.: +33 5 56 83 33 33; Fax: +33 5 56 33 33 49. E-mail: g.hurtevent@bordeaux.unicancer.fr
Received 4 November 2012 Revised 18 March 2013 Accepted 24 March 2013 Published 31 March 2013
DOI: http://dx.doi.org/10.14312/2052-4994.2013-14
Copyright: © 2013 Hugo C, et al. Published by NobleResearch Publishers. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.
AbstractTop
Objectives: To examine intra-observer reliability (IR) for lesion detection on contrast-enhanced breast magnetic resonance images (MRI) for screening women at high risk of breast cancer in single and joint double readings, without case selection. Methods: Contrast-enhanced breast MRIs were interpreted twice by the same independent reader and twice in joint readings. IR was assessed for lesion detection, normal MRI identification, mass, non-mass like enhancements (NMLE) and focus characterisation, and BI-RADS assessment. Results: MRI examinations for 124 breasts, 65 women (mean age 43.4y) were retrospectively reviewed with 110 lesions identified. Abnormal BIRADS (3-5) classifications were found for 52.3% in single readings and 58.5% in joint readings. Seven biopsies were performed for 4 histologically confirmed cancers. IR for BI-RADS classifications was good for single (0.63, 95% CI: 0.49-0.77), and joint readings (0.77, 95% CI: 0.61-0.93). IR for background parenchymal enhancement (BPE) was moderate across single (0.53, 95% CI: 0.40-0.65) and joint readings (0.44, 95% CI: 0.33-0.56). IR for BI-RADS category according to each enhancement was poor for single (0.27, 95% CI: 0.10-0.44), and higher for joint readings, (0.58, 95% CI: 0.43-0.72). Conclusions: IR in BI-RADS breast assessments or BI-RADS lesion assessments are better with joint reading in screening for women with high genetic risks, in particular for abnormal MRI (BI-RADS 3, 4 and 5).
Keywords: breast neoplasms; magnetic resonance imaging; genetic susceptibility; cancer screening; inter-observer variation
IntroductionTop
Around 5-10% of all breast cancers are hereditary and approximately half of these hereditary breast cancers are characterised by known mutations in the BRCA1 and BRCA2 genes. In this population, the risk of developing breast cancer is between 65-80% [1, 2], and cancers are particularly aggressive and occurs at young ages. In response to this high risk, current practice guidelines propose two options to women in addition to medical prophylaxis or ovariectomy: either surgery with bilateral prophylactic mastectomy, which is rarely accepted in France, or an intensive screening program to detect cancer at an early stage and to reduce breast cancer mortality. Initially, this screening programme included clinical breast examinations and annual mammography and started at 30 years of age [3–5]. In this group, sensitivity of mammography is under 50% [6], not only due to high density but also due to benign radiological presentation of the image and a rapid growth [7]. In addition, in mammography-based screening programs, up to 55% of detected cancers are interval cancers [8–13]. An alternative screening method consisting of annual contrast-enhanced magnetic resonance imaging (MRI) of the breast has been proposed for screening because of its high sensitivity (71-100%) [14–19].This method has recently been demonstrated to be superior to mammography for cancer detection for women at high familial risk [20].
To be reliable, a screening examination must be reproducible, yet up until now reproducibility has mostly been studied only for lesion detection and characterisation [21–26]. In almost all of these reports, the MRIs were suspect and lesions were annotated and confirmed with histopathology. Furthermore, mostly large masses were included across studies and only a few studies have examined non-mass-like enhancements (NMLE) or focus, although the aim of screening is to detect small cancers at early stages.
Thus, to increase intra-observer reproducibility of the contrast-enhanced breast MRI interpretation in this hereditary high-risk breast cancer population, we propose a joint-reading method, as has been proposed for mammographic screening for these patients [20]. We aim to compare intra-observer agreement between an independent reader’s double reading and joint double readings. We will evaluate intra-observer reproducibility for lesion detection, for normal MRI identification, for mass, NMLE and focus characterisation and Breast Imaging Reporting and Data System (BI-RADS) assessment, without case selection.
Materials and methodsTop
Patient selection
All asymptomatic women at high risk of breast cancer screened by breast dynamic
contrast-enhanced MRI at our institution between 2007 and 2009 were considered for
inclusion. High-risk women were defined as women known to be BRCA1, BRCA2 or TP53
gene mutation carriers or at high-risk (above 20%) of carrying a gene mutation,
without excluding women who had a personal cancer history. The patient’s first (or
only) MRI was considered in this study. Institutional review board approval was
obtained prior to the commencement of this retrospective study. Written informed
consent of patients was not required.
MRI protocol
Breast MRI was performed using a 1.5 Tesla scanner (INTERA, Philips). The patient
lay prone with the breast in a dedicated breast coil. The screening MRI examination
comprised of axial T2-weighted fast spin-echo images (TR: 2871 ms, TE: 110 ms, slice
thickness 3 mm) and dynamic three-dimensional fast spoiled gradient-echo axial or
sagittal T1-weighted sequences (TR: 9.3 ms, TE: 4.6 ms, slice thickness 1.2 mm),
for both breasts without fat saturation. The T1 images were collected before and
a few seconds after the beginning of the 14cc intravenous bolus injection of gadolinium
(Dotarem®, 0.5 mmol/mL, Guerbet). For each dynamic study, 5 to 7 sequences were
acquired (one sequence per 60-90s) and then for each sequence a subtraction image
was created. After the dynamic study, an axial T1 WATS fat-suppressed sequence was
obtained.
Study design and image interpretation
To assess intraobserver variability in this study, two radiologists (experienced
reader A, and junior reader B) reviewed the MRI across five readings in total. Reader
A interpreted the examinations twice independently (readings A1, A2), with a minimum
one-month interval between the readings. Reader B interpreted the examinations once
in preparation for the joint readings (B1), then the two readers reviewed each MRI
in a joint reading (C1), which was repeated one month later (C2). Intra-observer
variability in this study is the comparison of the two independent readings (A1-A2)
by an experienced radiologist and comparison across the two joint readings (C1-C2).
Data from the workstation (View forum, Philips) were used with multiplanar reconstruction, maximum-intensity projection and a kinetics analysis. Morphological analysis was interpreted on the native sequences where the lesion intensity was maximal. All breast lesions were interpreted and categorized according to the BI-RADS of American College of Radiology (ACR) classification [21]. The quality of the exam and any difficulties encountered with the reading were reported in the radiologists’ reports.
Background parenchymal enhancement (BPE) of the breast was classified into 4 categories reflecting a progressive level of difficulty for MRI interpretation: (1) absent or late non-intense homogenous enhancement; (2) early non-intense homogenous, late intense homogenous or late non-intense heterogeneous enhancement; (3) early intense homogenous, early non-intense heterogeneous or late intense heterogeneous enhancement; (4) early intense heterogeneous enhancement. ‘Early’ was defined as visible on the first sequence after injection at 60-90 seconds, ‘intense’ was defined as more intense than fatty tissue and ‘homogenous’ was employed according to the BI-RADS definition as confluent or uniform.
Previous MRI interpretation
Before inclusion in this study, all images had been interpreted by one of the radiologists
at the institution, including a BI-RADS assessment. The BI-RADS assessment distribution
per breast was 68.5% BI-RADS 1-2, 27.4% BI-RADS 3 and 4% BI-RADS 4-5. Per patient,
the BI-RADS assessment was 52.3% BI-RADS 1-2 (34 women), 40% BI-RADS 3 (26 women)
and 7.7% BI-RADS 4-5 (5 women) giving an overall recall rate of 47.7%. This data
was used as baseline comparison data. Histological confirmation via biopsy was proposed
for eight patients (12.3%) and seven agreed. Malignant tumours were found for 4
patients (6% of all patients included, or 57% positive predictive value (PPV) for
malignant tumours found across all lesions biopsied) and one atypical lesion (atypical
ductal hyperplasia and flat epithelial atypia).
Diagnostic interpretation
The two radiologists read the MRI examinations without access to the clinical, mammography
and ultra-sound data, nor to previous MRI interpretations. However, they were not
blinded to patient age, hormonal status, treatment and breast history (surgery,
radiotherapy). Each lesion was categorised by one of the five BI-RADS scores and
divided into BI-RADS 1-2, BI-RADS 3 or BI-RADS 4-5. Breasts were categorised according
to BI-RADS lesions, with the highest BI-RADS category retained for breasts with
multiple lesions. Very small foci (≤3 mm) were not reported, but foci of 4
and 5 mm were listed.
Statistical methods
To measure intra-observer reproducibility for lesion detection, normal MRI identification,
judgement of categorical enhancement, mass, NMLE, focus characterisation and BI-RADS
assessment, the kappa statistic was calculated for each pair of readings for the
single reader (A1,A2) and for the joint readings (C1, C2) and are reported with
95% confidence intervals (CI). Due to the small series size, it was not possible
to calculate the coefficient for the others items such as type of lesion (morphological
and dynamical) nor the sensitivity and specificity.
ResultsTop
Patient characteristics
MRI examinations for 65 women and 124 breasts (unilateral mastectomy in 6 patients)
were retrospectively reviewed. It was the first MRI screening for 30 patients (46%).
The mean patient age at the time of MR imaging was 43.4 years (min-max: 27-75).
Of the 65 patients, 25 had BRCA1 gene mutations, 27 had BRCA2 gene mutations and
13 had non-proven mutations. Twenty-one women had a personal breast cancer history
of either invasive carcinoma [17], ductal carcinoma in situ (DCIS) [1], or an association
of both [3] and this was bilateral for two women. Seventeen had previously received
breast radiotherapy on the imaged breast.
The image quality was considered poor for 6 images (9.2%) because of motion artefacts, and 12 images (18.5%) were judged as difficult to interpret because of a motion artefact [9], cardiac artefact [1], diffuse impeding BPE [3] or a technical issue [1].These images were however maintained for analyses as the quality of the image did not rule out a reliable clinical interpretation. Based on literature indicating that BPE is less frequent in menopausal women after radiotherapy treatment, BPE was examined according to whether the patient had radiotherapy and whether or not she was menopausal [22] (Table 1).
BPE | All breasts (n=124) | Post-menopausal women (n=34) | Radiotherapy (n=17) | |||
Single reader (A1-A2) | Joint readings (C1-C2) | Single reader (A1-A2) | Joint readings (C1-C2) | Single reader (A1-A2) | Joint readings (C1-C2) | |
Category 1 | 71.8-75.8% | 58-65.8% | 82.4-91.2% | 70.6-85.3% | 88.2-94.1% | 82.3-88.2% |
Category 2 | 21.1-15.3% | 13.8-16.3% | 5.9-8.8% | 0-11.8% | 0-11.8% | 5.9-11.7% |
Category 3 | 8.9-12.1% | 10.6-13.8% | 2.9-5.9% | 5.9-14.7% | 0-5.9% | 0 |
Category 4 | 0-4% | 9.8-12.2% | 0-2.9% | 2.9-8.8% | 0-5.9% | 5.90% |
One hundred and ten lesions were identified on the MR images for the 65 patients. The distribution of BI-RADS category across readings is given per breast (Table 2) and per lesion (Table 3). There were between 9.7 and 11.3% of BI-RADS 4/5 lesions depending on reading (comparable to “biopsy rates”). When considered per patient for comparison with “recall rates” in the literature, in the single readings, between 40-50.8% of patients were categorised as having BI-RADS 3-5 lesions (and thus requiring further analyses) and in the joint readings this rate varied from 52.3% to 53.8%. If we consider the PPV as the number of malignant tumours found across all lesions biopsied, we find thus a PPV of between 28-33% according to reading. The median size was 8 mm, focus 4mm, mass 8 mm and NMLE 17 mm across all lesions. Most lesions were <10 mm in size (65.7%). In terms of types of enhancement, lesions were classified as focus in 22.2-25.7% of cases, mass in 18.5-25.7%, and NMLE in 48.7-59.2% depending on the reading. BI-RADS 3 lesions were classified as focus in 12.2-33.3% of cases, mass in 18.2-26.5% and NMLE in 48.5-68.5%.
Reader-A 1 | Reader-A2 | Joint reading-C1 | Joint reading-C2 | |
BI-RADS 1 or 2 | 94 (75.8%) | 85 (68.5%) | 82 (66.1%) | 83 (66.9%) |
BI-RADS 3 | 18 (14.5%) | 26 (21.0%) | 30 (24.2%) | 27 (21.8%) |
BI-RADS 4 or 5 | 12 (9.7%) | 13 (10.5%) | 12 (9.7%) | 14 (11.3%) |
†”Recall rate” = rate of women with BI-RADS 3-5 lesions
81 breasts described over both readings | 97 breasts described over both readings | |||
Single reader-A1 | Single reader-A2 | Joint reading-C1 | Joint reading-C2 | |
Lesions described (n) | 53 | 74 | 79 | 86 |
BI-RADS 1-2 | 10 (19%) | 11 (15%) | 17 (22%) | 17 (20%) |
BI-RADS 3 | 33 (68%) | 50 (63%) | 50 (63%) | 55 (64%) |
BI-RADS 4-5 | 13 (18%) | 13 (15%) | 12 (15%) | 14 (16%) |
Intra-observer reliability
For BI-RADS classification per breast, 83.9% of the single readings were concordant
and 91% of joint readings were concordant. Intra-observer reliability was good for
single readings, kappa =0.63, 95% CI: 0.49-0.77, and for joint readings, kappa =0.77,
95% CI: 0.63-0.91. In terms of concordance rates for BI-RADS category, for BI-RADS
1-2 categories (for breast classified as BI-RADS 1-2 on at least one of the readings),
the concordance rate was 84.5% for the independent reader and 87.5% for the joint
reading (82/97 and 77/88 breasts respectively). Concordance for BI-RADS 3-5 (equivalent
to recall rates) was lower at 52% (22/42 breasts) for single readings and 70% (33/47
breasts) for joint readings.
Intra-observer reliability for BPE was moderate across single readings, kappa =0.53, 95% CI: 0.40-0.65, and across joint readings, kappa =0.44, 95% CI: 0.33-0.56 (Table 4). We also analysed reliability according to the overall BI-RADS category in subgroups of patients based on BPE reported in the second independent reading (categories 1 and 2 or categories 3 and 4). Intra-observer reliability of BI-RADS category across single readings was good when BPE was not serious (categories 1 and 2), kappa =0.69, 95% CI: 0.55-0.83 with 87% concordant cases (94/108 breasts). Intra-observer reliability could not be calculated across categories 3 and 4 due to the small number but 62.5% of the cases were concordant (10/16 breasts). For joint readings, intra-observer reliability of BI-RADS category was good for BPE categories 1 and 2: kappa =0.69, 95% CI: 0.55-0.83 with 90.1% concordant cases (82/91 breasts). It was not possible to calculate intra-observer reliability within categories 3 and 4 but 87.5% of cases were concordant (28/32 breasts).
Single reading intra-observer reliability | Joint reading intra-observer reliability | |
Kappa value [95% confidence interval] | Kappa value [95% confidence interval | |
BI-RADS classification overall | 0.63 | 0.77 |
[0.49-0.77] | [0.63-0.91] | |
Background parenchymal enhancement | 0.53 | 0.44 |
[0.40-0.65] | [0.33-0.56] | |
BI-RADS category for category 1 and 2 background parenchymal enhancement | 0.69 | 0.77 |
[0.55-0.83] | [0.61-0.93] | |
BI-RADS category according to lesion | 0.27 | 0.58 |
[0.10-0.44] | [0.43-0.72] | |
Lesion type (mass, focus, non-mass-like enhancement) | 0.34 | 0.44 |
[0.21-0.46] | [0.32-0.56] |
Intra-observer reliability was calculated for BI-RADS category according to each enhancement. Lesions that were not described on one of the readings were classified as BI-RADS1 or 2 (as not classified as a suspect or undetermined lesion). Reliability was poor for single readings, kappa =0.27, 95% CI: 0.10-0.44 and higher for joint readings 0.58, 95% CI: 0.43-0.72, but concordance rates for cases with no lesions were good: 54%, joint and 62%, single.
Reliability was also calculated according to the type of enhancement (mass, focus, NMLE) with moderate reliability for single readings, kappa =0.34, 95% CI: 0.21-0.46. When the lesion type was concordant, the BI-RADS category was the same in 81% of cases (36/37) and when it was discordant, the BI-RADS category was the same in only 50% of cases (4/8). Joint reading reliability was moderate, kappa =0.44, 95% CI: 0.32-0.56. When the lesion type was concordant the BI-RADS category was the same in 100% of cases (56/56) and when it was discordant, the BI-RADS category was the same in only 60% of cases (6/10).
DiscussionTop
Our study population is comparable with other high genetic risk populations in the literature in terms of cancer detection and biopsy rates. Our cancer detection rate of 6% (4 of 65 patients) is comparable to 1.7% [23] reported in a review of five prospective studies, 4% in the recent EVA trial [29] and 8-9 % in other series [6, 24]. Our rate of BIRADS 4/5 lesions, which is approximately equivalent to ‘biopsy rates’ in the previous interpretation and in the literature, was between 9.7% and 11.3%, compared to 12.3% in the previous interpretation, and 8.3% [25] and 13% [31] in the literature. The PPV is between 28-33% compared to 17-57% [26] in the literature and 57% in the previous MRI interpretation. The recall rate is 40-50.8% of patients in the single readings, 52.3-53.8% in joint readings and 47.7% in the previous MRI interpretation, higher than previously reported at 8-17% in other annual screening studies [23, 24, 27-29], probably due to an overuse of the BI-RADS3 category as discussed further.
Intra-observer reliability
Reproducibility has mostly been assessed only for description and characterisation
of lesions. Only one study, MARIBS, has looked at the reproducibility of detection
of lesions [28]. This study was a performance test on 8 selected cases where the
BI-RADS assessment was made on the whole breast. Other screening studies date either
from before the BIRADS classification [30, 31] or assess only pathological MRIs
and focussed mostly on inter-observer rather than intra-observer reliability.
Background parenchymal enhancement (BPE)
In our study, 70 to 88% of exams were categories 1-2 and 12-25% were categories
3-4, so we can consider that this categorisation distinguishes enhancement types.
Intra-observer agreement observed in our study for BPE was moderate (0.44-0.53)
in both independent and joint readings. The agreement was not affected by enhancement
intensity, similar to breast density reported by mammography (0.46-0.59) [32]. Most
of our mismatches occurred between categories 1 and 2 which has limited clinical
impact. However, one of the major difficulties was identifying BPE from NMLE (discussed
further). In clinical practice, when parenchymal glandular enhancement is suspected,
a control MRI performed 15 days later in a different part of the menstruation cycle,
could be indicated. It is notable that a high number of post-menopausal women and
patients having received radiotherapy had BPE, in contrast to what could be expected
according to the literature [22].
Breast BI-RADS assessment
Concordance rates reach 84% for all breasts in single reading and 91% in joint reading
and the kappa-values are good at respectively 0.63 and 0.77. These results are in
accordance with the previous agreement rate of 87% [33] reported by Warren et al
in a screening study, and indicate that joint readings are more reliable than independent
readings.
Our study shows good reproducibility for normal examinations (BI-RADS1-2) which represent the largest group of MRIs (66-76%). In this population reproducibility is not considerably improved with the joint reading (84.5% single to 87.5% joint). Concerning abnormal examinations (BI-RADS 3-4-5), improvement is more marked (from 52% in single to 70% in joint). The good reproducibility for normal examination and lower for abnormal indicates that variability is higher in characterisation than in detection. This is important to underline because the first role of the radiologist in screening is to recognise normal examinations, which are the more frequent, from abnormal examinations. The results of this study indicate that joint reading should be proposed preferentially for all abnormal MRIs. It should be noted that both radiologists prepared for the joint reading independently to strengthen individual impressions and reduce the chance of influencing each other.
BI-RADS assessment of lesions
Intra-observer agreement for BI-RADS assessment of lesions according to each enhancement
improves with joint reading. The kappa values are relatively low, but were only
calculated on cases where lesions were observed and do not take into account the
high rates of concordant cases (54%, joint and 62%, single) with no lesions. The
two most noteworthy discordant causes are BPE and lesion size. Indeed, for small
lesions around 5 mm, it is difficult to distinguish between a focus and a focal
NMLE. This has a clinical impact as multiple foci are BI-RADS 2 and multiple focal
NMLE are BI-RADS 3.
Intra-observer agreement on type of lesion (mass, NMLE, focus) improves from fair with single readings to moderate with the joint readings. The same BI-RADS assessment was attributed in more than 80% when the type of lesion was concordant and in less of 60% in case of discordant types. This highlights the necessity to improve the BI-RADS definition and the MRI spatial definition, particularly for lesions surrounded by fat or by glandular tissue. Concerning the BI-RADS assessment of lesions in the literature, only inter-observer agreement had been reported with 0.57 and 0.45 kappa-values, but in those studies only large masses were included (12-23 mm) and, as Stoutjesdijk et al. [34] highlight, masses are the most easily type of lesion to describe and variability increases with NMLE.
The BIRADS 3 assessments rate (21-34% women) is higher than in the literature (6.6-25%) [26, 30, 32, 35-37]. Among our BI-RADS 3 assessments, we referenced 18% masses, as reported in Eby et al.[35]; but respectively 68.5% and 36% NMLE. Our high rate may be explained by an overuse of the NMLE description and BI-RADS3 classification for BPE. Others articles have reported the same difficulties, especially in the early years of clinical practice [35, 36]. Having more objective criteria to recognize BPE for BI-RADS 3 enhancements should improve intra-observer agreement.
Limitations
The main limit of our study is that it is a retrospective study at a single centre
where the junior reader was trained by the senior reader. Further, the MRI interpretations
in our study differ from those performed in daily clinical practice because the
clinical, mammographic and ultra-sound data and prior MRI were not available to
the readers. A further limiting factor is the small number of cases (65 women and
124 breasts) which does not allow the calculation of kappa-values within each lesion
type nor the calculation of sensitivity and specificity.
ConclusionTop
Overall, the parenchymal enhancement classification seems to categorise the population well and to be reproducible, but it is essential to study the performance of MRI according to the category of BPE. Intra-observer agreement in BI-RADS breast assessments or BI-RADS lesion assessments are improved with joint reading in screening for women with high genetic risks, in particular for abnormal MRI (BI-RADS 3, 4 and 5). For normal MRI, the intra-observer agreement is good for single readings and is not improved with the joint reading. The joint reading of all MRI (normal and abnormal) led to increased monitoring of some ‘in-between’ patients (BI-RADS3) without increasing the biopsy rate. Given the importance of establishing a reliable screening programme for these women at high risk, this study evaluating inter-rater reliability without case selection including normal MRI, small lesions and non MLE provides useful data. Future research on joint reading for MRI screening for women with high genetic risk of breast cancer could be useful for the improvement of MRI performance with a specific focus on determining what kind of joint reading is optimal, in which population, and whether the results warrant the costs involved.
Conflict of interest
The authors wish to express that they have no conflict of interest.
Acknowledgements
We thank Pippa McKelvie-Sebileau for English medical writing assistance.
ReferencesTop
[1] Antoniou A, Pharoah PD, Narod S, Risch HA, Eyfjord JE, et al. (2003) Average risks of breast and ovarian cancer associated with BRCA1 or BRCA2 mutations detected in case Series unselected for family history: a combined analysis of 22 studies. Am J Hum Genet 72:1117–1130. Article Pubmed
[2] Ford D, Easton DF, Bishop DT, Narod SA, Goldgar DE (1994) Risks of cancer in BRCA1-mutation carriers. Breast Cancer Linkage Consortium. Lancet 343:692–695. Article Pubmed
[3] Burke W, Daly M, Garber J, Botkin J, Kahn MJ, et al. (1997) Recommendations for follow-up care of individuals with an inherited predisposition to cancer. II. BRCA1 and BRCA2. Cancer Genetics Studies Consortium. JAMA 277:997–1003. Article Pubmed
[4] Pichert G, Bolliger B, Buser K, Pagani O (2003) Evidence-based management options for women at increased breast/ovarian cancer risk. Ann Oncol 14:9–19. Article Pubmed
[5] Vasen HF, Haites NE, Evans DG, Steel CM, Møller P, et al. (1998) Current policies for surveillance and management in women at risk of breast and ovarian cancer: a survey among 16 European family cancer clinics. European Familial Breast Cancer Collaborative Group. Eur J Cancer 34:1922–1926. Article Pubmed
[6] Bigenwald RZ, Warner E, Gunasekara A, Hill KA, Causer PA, et al. (2008) Is mammography adequate for screening women with inherited BRCA mutations and low breast density? Cancer Epidemiol Biomarkers Prev 17:706–711. Article Pubmed
[7] Schrading S, Kuhl CK (2008) Mammographic, US, and MR imaging phenotypes of familial breast cancer. Radiology 246:58–70. Article Pubmed
[8] Schrading S, Kuhl CK (2008) Mammographic, US, and MR imaging phenotypes of familial breast cancer. Radiology 246:58–70. Article Pubmed
[9] Brekelmans CT, Seynaeve C, Bartels CC, Tilanus-Linthorst MM, Meijers-Heijboer EJ, et al. (2001) Effectiveness of breast cancer surveillance in BRCA1/2 gene mutation carriers and women with high familial risk. J Clin Oncol 19:924–930. Article Pubmed
[10] Gui GP, Hogben RK, Walsh G, A'Hern R, Eeles R (2001) The incidence of breast cancer from screening women according to predicted family history risk: Does annual clinical examination add to mammography? Eur J Cancer 37:1668–1673. Article Pubmed
[11] Macmillan RD (2000) Screening women with a family history of breast cancer--results from the British Familial Breast Cancer Group. Eur J Surg Oncol 26:149–152. Article Pubmed
[12] Murday V, Pears R, Ball J, Eeles R, Hodgson S (2004) An audit of screening for familial breast cancer before 50 years in the South Thames Region - have we got it right? Fam Cancer 3:29–34. Article Pubmed
[13] Scheuer L, Kauff N, Robson M, Kelly B, Barakat R, et al. (2002) Outcome of preventive surgery and screening for breast and ovarian cancer in BRCA mutation carriers. J Clin Oncol 20:1260–1268. Article Pubmed
[14] Christensen EE, Murry RC, Holland K, Reynolds J, Landay MJ, et al. (1981) The effect of search time on perception. Radiology 138:361–365. Article Pubmed
[15] Federle MP, Gur D (1995) Double reading of certain examinations such as barium enemas and mammograms can increase sensitivity at the expense of specificity. AJR Am J Roentgenol 164:1291–1292. Article Pubmed
[16] Krupinski EA (2005) Visual search of mammographic images: influence of lesion subtlety. Acad Radiol 12:965–969. Article Pubmed
[17] Mello-Thoms C, Hardesty L, Sumkin J, Ganott M, Hakim C, et al. (2005) Effects of lesion conspicuity on visual search in mammogram reading. Acad Radiol 12:830–840. Article Pubmed
[18] Nodine CF, Mello-Thoms C, Kundel HL, Weinstein SP (2002) Time course of perception and decision making during mammographic interpretation. AJR Am J Roentgenol 179:917–923. Article Pubmed
[19] Zakaria S, Brandt KR, Degnim AC, Thomsen KM (2009) Patients' perceptions of breast MRI: a single-center study. AJR Am J Roentgenol 192:1149–1154. Article Pubmed
[20] Namer M, Gligorov J, Luporsi E, Serin D (2008) Recommandations pour la Pratique Clinique : Saint Paul de Vence 2007. Cancers du sein 14:38. Article
[21] Ikeda D, Hylton N, Kuhl C, et al. (2003) Breast Imaging Reporting and Data System, ACR BI-RADS—breast imaging atlas. BI-RADS: magnetic resonance imaging, 1st ed In: D'Orsi C, Mendelson E, Ikeda D, et al., editors. Reston, VA: American College of Radiology.
[22] Taourel P, Prat X, Granier C, et al. (2007) IRM du sein Montpellier: Sauramps médical.
[23] Sardanelli F, Podo F (2007) Breast MR imaging in women at high-risk of breast cancer. Is something changing in early breast cancer detection? Eur Radiol 17:873–887. Article Pubmed
[24] Kuhl CK, Schrading S, Leutner CC, Morakkabati-Spitz N, Wardelmann E, et al. (2005) Mammography, breast ultrasound, and magnetic resonance imaging for surveillance of women at high familial risk for breast cancer. J Clin Oncol 23:8469–8476. Article Pubmed
[25] Kuhl C, Weigel S, Schrading S, Arand B, Bieling H, et al. (2010) Prospective multicenter cohort study to refine management recommendations for women at elevated familial risk of breast cancer: the EVA trial. J Clin Oncol 28:1450–1457. Article Pubmed
[26] Lehman CD (2006) Role of MRI in screening women at high risk for breast cancer. J Magn Reson Imaging 24:964–970. Article Pubmed
[27] Kriege M, Brekelmans CT, Boetes C, Besnard PE, Zonderland HM, et al. (2004) Efficacy of MRI and mammography for breast-cancer screening in women with a familial or genetic predisposition. N Engl J Med 351:427–437. Article Pubmed
[28] Leach MO, Boggis CR, Dixon AK, Easton DF, Eeles RA, et al. (2005) Screening with magnetic resonance imaging and mammography of a UK population at high familial risk of breast cancer: a prospective multicentre cohort study (MARIBS). Lancet 365:1769–1778. Article Pubmed
[29] Warner E, Plewes DB, Hill KA, Causer PA, Zubovits JT, et al. (2004) Surveillance of BRCA1 and BRCA2 mutation carriers with magnetic resonance imaging, ultrasound, mammography, and clinical breast examination. JAMA 292:1317–1325. Article Pubmed
[30] Ikeda DM, Hylton NM, Kinkel K, Hochman MG, Kuhl CK, et al. (2001) Development, standardization, and testing of a lexicon for reporting contrast-enhanced breast magnetic resonance imaging studies. J Magn Reson Imaging 13:889–895. Article Pubmed
[31] Mussurakis S, Buckley DL, Coady AM, Turnbull LW, Horsman A (1996) Observer variability in the interpretation of contrast enhanced MRI of the breast. Br J Radiol 69:1009–1016. Article Pubmed
[32] Nicholson BT, LoRusso AP, Smolkin M, Bovbjerg VE, Petroni GR, et al. (2006) Accuracy of assigned BI-RADS breast density category definitions. Acad Radiol 13:1143–1149. Article Pubmed
[33] Warren RM, Pointon L, Thompson D, Hoff R, Gilbert FJ, et al. (2005) Reading protocol for dynamic contrast-enhanced MR images of the breast: sensitivity and specificity analysis. Radiology 236:779–788. Article Pubmed
[34] Stoutjesdijk MJ, Fütterer JJ, Boetes C, van Die LE, Jager G (2005) Variability in the description of morphologic and contrast enhancement characteristics of breast lesions on magnetic resonance imaging. Invest Radiol 40:355–362. Article Pubmed
[35] Eby PR, DeMartini WB, Gutierrez RL, Lehman CD (2010) Probably benign lesions detected on breast MR imaging. Magn Reson Imaging Clin N Am 18:309–321. Article Pubmed
[36] Eby PR, DeMartini WB, Gutierrez RL, Saini MH, Peacock S, et al. (2009) Characteristics of probably benign breast MRI lesions. AJR Am J Roentgenol 193:861–867. Article Pubmed